IOS355I
PORT ADDRESS pp OF SWITCH DEVICE dddd text

Explanation

A port of a switch device has had its participation in dynamic channel path management affected.
Note: This message may appear for FICON® attached devices even though they do not support DCM.
In the message text:
pp
The port address of the switch device.
dddd
The switch device number.
text
Can be one of the following:
TAKEN OFFLINE TO DCM - NODE DESCRIPTOR NOT CURRENT
The port of the switch device has been taken offline from participating in dynamic channel path management because the node descriptor of the channel or subsystem attached to the port is not current.
BROUGHT ONLINE TO DCM - NODE DESCRIPTOR NOW CURRENT
The port of the switch device has been brought online to participate in dynamic channel path management because the node descriptor of the channel or subsystem attached to the port is now current.

System action

Processing continues.

Operator response

None.

Source

Input/output supervisor (IOS)

Module

IOSVSWRB