IEC161I (return code 195)
rc[(sfi)]-ccc,jjj, sss,ddname,dev,ser,xxx, dsname,cat

Explanation

For general information about message IEC161I, see the explanation for return code 001.

Specific information for this return code: An error occurred attempting to extend a VSAM striped component.
  • ccc = 220 - IDA0557E: ALLOCSPC. Unexpected extend error.

    The SFI field in the message, if present, is of the format (rc,rsn) where rc=return code and rsn=reason code from IDA0557F.

  • ccc = 220 - IDA0557E: ALLOCSPC. Unexpected extend error.

    The SFI field in the message is of the format (rc,rsn) where rc=return code and rsn=reason code from IDA0557F.

    • When message IEC070I is issued with a return code of 195 and an SFI value of (00000004,00000009), it means the following:

      An attempt to extend a striped data set failed because the amount of space returned by DADSM was not the same as the amount of space requested.

    • When message IEC070I is issued with a return code of 195 and an SFI value of (00000004,0000000A), it means the following:

      The amount of space returned by DADSM was not a multiple the VSAM data set control area size. This condition normally results when a user or OEM implements an exit routine (such as IGGPRE00) associated with the IGGPRE00_EXIT preprocessing dynamic exit that modifies the space amount requested.

    • When message IEC070I is issued with a return code of 195 and an SFI value of (00000004,0000000B), it means the following: A GETMAIN failure occurred when requesting space for a catalog parameter list from subpool 230, during extend processing.
  • ccc = 220 - IDA0557E: CATALC. SFI = 32. NO UCB address returned from call to IDA0557F.
  • ccc = 221 - IDA0557E: CATALC. SFI = 32. Unexpected extend error from call to IDA0557F.

    The SFI field in the message is of the format (rc,rsn) where rc=return code and rsn=reason code from IDA0557F.

System action

EOV processing ends for the data set.

Programmer response

Correct the error and rerun the job.

Programmer response

If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM Support Center. Provide the SYSOUT output, including the entire text of any IEC messages.

Module

IDA0557E

Routing code

11

Descriptor code

6