For general information about message IEC161I, see the explanation for return code 001.
Specific information for this return code: An extend was attempted, but no secondary space allocation quantity was specified. See the discussion in Access Method Services for ICF, under the description for secondary space amount, for further details.
For the case of an Extended Format data set using a data class including 'Additional Volume Amount' set to secondary, the data class will have to be altered to set 'Additional Volume Amount' to primary and the data set redefined, or the data set must be redefined with a data class that does not include 'Additional Volume Amount' set to secondary, or the data set redefined to include a secondary space allocation.
Extend processing is ended for this data set.
Scratch unneeded data sets from the volume, or run an access method services ALTER command to add more candidate volumes to the catalog entry for the data set, or specify a secondary space quantity.
IDA0557E, IDA0557X, IDA0557A
11