Explanation
For general information about message IEC161I,
see the explanation for return code 001.
Specific information
for this return code: The EOV routine was unable to extend the data
set due to a critical error in the previous EOV space allocation.
- ccc = 215
- An extend of a striped data set failed because a previous EOV
extend has failed.
- For data sets defined with Share Options 3 or 4, you might see
this message if one job is attempting EOV while another job is extending
the data set due to improper serialization by the application.
System action
The OPEN OR EOV fails. If OPEN, the error flag
(ACBERFLG (ACBERFLG) in the ACB (access method block) for the data
set for OPEN is set to 88 (X'58'). For data sets defined
with Share Options 3 or 4, make sure that the application program
uses ENQ/DEQ to maintain data integrity while sharing the data set.
Routing code
Descriptor code