IEC161I (return code 054)
rc[(sfi)]-ccc,jjj, sss,ddname,dev,ser,xxx, dsname,cat

Explanation

For general information about message IEC161I, see the explanation for return code 001.

Specific information for this return code: The ACB (access method control block) indicated keyed accessing, but the data set is not a key-sequenced data set.

System action

OPEN processing ends for the data set. The error flag (ACBERFLG) in the ACB (access method block) for the data set is set to 160 (X'A0').

Programmer response

Make sure that the type of accessing indicated in the ACB is consistent with the data set being opened.

Module

NONE

Routing code

11

Descriptor code

6