IEC161I (return code 047)
rc[(sfi)]-ccc,jjj, sss,ddname,dev,ser,xxx, dsname,cat

Explanation

For general information about message IEC161I, see the explanation for return code 001.

Specific information for this return code: The ACB (access method control block) specifies improved control interval processing but the data set attributes are not consistent with this mode of access. One of the following errors was detected:
  • Physical block size was not equal to control interval size.
  • The data set was not an entry-sequenced data set or the data/index component of a key-sequenced data set.
  • The data set was an index with IMBED or REPLICATE specified.

System action

OPEN processing ends for the data set. The error flag (ACBERFLG) in the ACB (access method block) for the data set is set to 160 (X'A0').

Programmer response

Correct the indicated error and rerun the job.

Module

IDA0192A, IDA0192B

Routing code

11

Descriptor code

6