IEC161I (return code 024)
rc[(sfi)]-ccc,jjj, sss,ddname,dev,ser,xxx, dsname,cat

Explanation

For general information about message IEC161I, see the explanation for return code 001.

Specific information for this return code: RLS OPEN for INPUT and invalid BWO (backup while open) flags in catalog.

System action

Open processing is ended for the data set. The error flag (ACBERFLG) in the ACB (access method block) for the data set is set to 183 (X'B7').

Programmer response

None. This message is informational. Any required action will be taken by the subsystem (for example, CICS).

Module

IDAV192C

Routing code

11

Descriptor code

6