IEE860I
xx SIZE MUST BE BETWEEN 16K AND 999K

Explanation

A TRACE MT command requested that the system turn master tracing on or off or change the size of the master trace table. The TRACE command specified an incorrect size for the MT parameter.

System action

The system rejects the command. The system does not change the status of master trace or the size of the existing master trace table.

Operator response

Enter the TRACE command again, either:
  • Omitting the nnnK portion of the MT parameter to allow the master trace table size to default to the value specified during initial program load (IPL).
  • Specifying a valid table size in K bytes. The minimum allowable size is 16K bytes; the maximum size is 999K bytes.

Source

Master scheduler

Module

IEECB806

Routing code

*

Descriptor code

5