The system is unable to process the PAGEADD command as requested.
The PAGEADD command requested that the data set be added to the system page/swap data sets. However, the system is already using the data set as a page/swap data set.
Processing for the PAGEADD command could not add the data set to the system because
While attempting to add the page/swap data set, the PAGEADD command could not obtain enough system queue area (SQA) to build the control blocks needed for the data set.
Processing for the PAGEADD command could not open the page/swap data set because the volume containing the data set was not mounted.
During PAGEADD processing, the system determined that the data set resides on a device type not supported for page/swap data sets.
Processing for the PAGEADD command could not add the data set to the system because of an I/O error on the cached auxiliary storage subsystem.
The PAGEADD command requested that the data set be added; however it is already in use as the replacement data set in a PAGEDEL REPLACE command.
The PAGEADD command requested that a swap data set be added; however, swap data sets are no longer supported.
The system was unable to obtain an ENQ of SYSZILRD dsname.volser for page data sets during a PAGEADD command. The page data set may be in use by another system.
The system continues processing the PAGEADD command.
The system continues processing the PAGEADD command.
The system continues processing the PAGEADD command.
The system continues processing the PAGEADD command.
The system continues processing the PAGEADD command.
The system continues processing the PAGEADD command.
The system continues processing the PAGEADD command.
The system continues processing the PAGEADD command.
The data set is not processed.
The data set is not processed.
If the data set name was entered incorrectly, reenter the command specifying the correct data set name.
NOT CATALOGED
To add the data set as a page or swap data set, do one of the following:
INSUFFICIENT STORAGE TO PROCESS THIS DATA SET
Reenter the PAGEADD command. If the problem persists, increase the size of the SQA at the next IPL.
VOLUME NOT MOUNTED - DATA SET WILL NOT BE PROCESSED
Mount the requested volume. Reenter the command.
HAS AN INVALID DEVICE TYPE
Inform the system programmer that a problem occurred in the ASM control blocks or code.
NOT ALLOCATED - ERROR CODE xxxx INFORMATION CODE yyyy
Inform the system programmer that a problem occurred during data set allocation, and pass along the error and information codes.
If the data set name was entered incorrectly, Reenter the command specifying the correct data set name.
SWAP DATA SETS NO LONGER SUPPORTED
None.
COULD NOT BE SERIALIZED
This situation indicates a problem in ASM control blocks or code. Verify that the VSAM catalog entries for the page and swap data sets have not been altered erroneously. If they have not been altered erroneously, try to recatalog them.
I/O ERROR DETECTED - DATA SET UNUSABLE
Look up the SVC 99 error and information codes in z/OS MVS Programming: Authorized Assembler Services Guide.
ALREADY IN USE BY PAGEDEL REPLACE COMMAND
Auxiliary storage manager (ASM)
ILRPGEXP