IEE611I
ONE OR MORE COMMAND USER EXITS COULD NOT BE LOADED

Explanation

In response to a SET MPF command, the system could not load one or more command installation exit routines.

System action

Processing continues without the exit routine(s). The system issues message CSV003I or CSV016I to identify the routines that were not loaded.

System programmer response

Check to see if one or more of the following occurred:
  • The load module library was specified incorrectly.
  • The load module library does not contain the requested installation exit routine.

Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.

Source

Communications task (COMMTASK)

Module

IEECB805

Routing code

2,10

Descriptor code

5