IEC952I
004 CONFLICTING/INVALID DCB FUNC OR RELATED PARAMETER

Explanation

This is an explanatory message for system completion code 004. A conflicting or incorrect DCB parameter (FUNC or related parameter) was specified. The hex contents of register 15 indicate the nature of the error:
Register 15
Explanation
01
An incorrect DCB FUNC parameter was specified.
02
An incorrect combination of the DCB FUNC parameter and CNTRL macro instruction was specified.
03
Conflicting associated data set access methods were specified.
04
An incorrect DCB was specified with a 3505 or 3525.

System action

The system ends the task.

System programmer response

If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the program listing for the job.

Programmer response

Probable user error. Verify the referenced fields and rerun the job.

Source

DFSMSdfp

Module

IGG0197N

Routing code

11

Descriptor code

6