IEC907I
744 SYNADAF ERROR, SVC DUMP TRIED, RC = rc.

Explanation

An error occurred during the processing of SYNADAF or SYNADRLS. The SYNADAF task recovery routine received control during task end after a program check in a SYNADAF or SYNADRLS module. In the message text, 744 associates this message with system completion code 744.

In the message text:
rc
The return code that indicates the results of an SVC Dump attempt as follows:
  • 0 - Successful dump.
  • 4 - Partial dump.
  • 8 - No dump.

System action

The SVC Dump written to the SYS1.DUMP or user-designated data set contains the CPU prefixed storage area, nucleus, system queue area, and the user's address space. The dump header contains the job name, step name, procedure step name, system completion code 744, and the SYNADAF first load module name, IGC0006H. A software error record is written to the logrec data set. Task end continues.

System programmer response

If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the JCL, the program listing for the job, and the logrec data set error record.

Programmer response

Rerun the job step.