IEC900I
INVALID ABEND CODE PASSED TO MODULE mod

Explanation

The module is an OPEN/CLOSE/EOV problem determination routine. It did not recognize the passed abnormal end code, so it issued an Fxx abnormal end code where xx is one of the following:
  • 13 for OPEN
  • 14 for CLOSE
  • 17 for CLOSE TYPE=T
  • 37 for EOV.
This might be an error in system logic, possibly caused by an incorrect combination of PTFs.

Register 12 contains the abnormal end code passed to the module.

In the message text:
mod
The specified module.

System action

The system ends the task.

System programmer response

If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the SYSOUT output for the job.

Source

DFSMSdfp

Module

IFG0190P, IFG0200P, IFG0230P, IFG0550P, IGG0196M

Routing code

11

Descriptor code

6