IEC537I
BLOCK COUNTS: DEVICE | TLABEL=xxxx DCB=yyyy

Explanation

At EOV time, a block count mismatch was detected. The count computed from hardware device information does not match the count computed by the access method or application program. A block count mismatch results in one of three system completion codes:
  • abend 237, reason code 0C;
  • abend 214, reason code 10; or
  • abend 117, reason code 3C.
In the message text:
xxxx
The count computed from either the hardware device information or recorded in the tape label.
yyyy
The count computed by the access method or application program.

System action

The system abnormally ends the task, and issues an accompanying message that further describes the error condition. For abend 237, the system issues IEC023I; for abend 214, IEC210I; and for abend 117, IEC218I.

Programmer response

Refer to IEC023I, IEC210I, or IEC218I for an appropriate response.

Source

DFSMSdfp

Module

IFG0200Y

Routing code

11

Descriptor code

-