IEC177I
dev CHARACTER ARRANGEMENT TABLE FOR COPY MODIFICATION mod NOT SPECIFIED

Explanation

A SETPRT macro instruction was issued for a 3800 printer, and the MODIFY parameter specified copy modification table. The table reference character (TRC) subparameter was specified, but it contained an error. Either the value for the TRC was incorrect (4 or greater), or there is no character arrangement table in the position specified by TRC value.

In the message text:
dev
The device number of the specified device.
mod
The specified module.

System action

SETPRT processing ends and places a return code in register 15.

Programmer response

If the value specified for the TRC subparameter is incorrect (4 or greater), respecify it correctly. If there is no character arrangement table in the position specified on the TRC subparameter, either use the CHARS parameter to load a character arrangement table in that position or specify a different position on the TRC subparameter.

Source

DFSMSdfp

Module

IGG08112