IEC173I
dev I/O ERROR ON text

Explanation

text is one of the following:
  • PREVIOUS OUTPUT
  • BLOCKING OR UNBLOCKING DATA CHECKS

A SETPRT macro instruction was issued for 3800 printer dev. If I/O ERROR ON PREVIOUS OUTPUT appears in the message text, a permanent I/O error occurred during a previous output operation. If I/O ERROR BLOCKING OR UNBLOCKING DATA CHECKS appears in the message text, a permanent I/O error occurred while SETPRT processing was running an internal channel command that blocks or unblocks data checks. Message IOS000I, giving details about the I/O error, precedes this message.

In the message text:
dev
The device number of the specified device.

System action

If I/O ERROR ON PREVIOUS OUTPUT appears, the system enters the error analysis (SYNAD) routine when it encounters the next PUT or CHECK macro instruction. In all cases, SETPRT processing ends and places a return code in register 15.

Operator response

Notify the system programmer. Respond as indicated for message IOS000I.

Programmer response

Follow your installation's procedures for correcting the permanent I/O error.

Source

DFSMSdfp

Module

IGC0008A