Explanation
The parameter passed to the data management routine
for 3886 support was incorrect. The operation can be one of the following:
- RD LINENO
- An attempt to read backwards was made (for example, a line number
less than the last line read was specified) or the support detected
two EOP conditions on successive reads with no eject between them.
- LINEFMAT
- The line format number specified was greater than 63.
- NUM TIME MKS
- The number of timing marks specified on an eject was greater than
33.
- NO LINE FMAT
- No line format number specified for read.
- LINE MK CODE
- The code specified for a line mark was greater than 15.
- LINE NK NO
- The line number to be marked was greater than 33.
- DOC CODE
- The code specified for a document mark was greater than 15.
In the message text:
- prm
- The parameter specified.
- opr
- The operation specified.
System action
Processing continues. An I/O error will be caused
by the incorrect data passed to the device.
System programmer response
If the error recurs and the program
is not in error, look at the messages in the job log for more information.
Search problem reporting data bases for a fix for the problem. If
no fix exists, contact the IBM® Support
Center. Provide the program listing for the job.
Programmer response
Correct the incorrect data specification
and rerun the job.
Source
Module
Routing code
Descriptor code