IEB802I
I/O ERROR jjj, sss, ddd, devtyp, ddname, op, err, xxxx, acc

Explanation

A permanent input/output error occurred while processing on the device.

In the message text, the error analysis information provided by the SYNADAF data management macro instruction issued in the SYNAD routine was:
jjj
Job name.
sss
Step name.
ddd
Device number of the device.
devtyp
Device type.
ddname
Data definition name.
op
Operation attempted.
err
Error description.
xxxx
Track address or relative block number.
acc
Access method.

System action

The program is ended. The return code is 12.

System programmer response

If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the JCL and all printed output and output data sets related to the problem.

Programmer response

Correct the error condition indicated in the message text.

Source

DFSMSdfp

Routing code

11

Descriptor code

7