IEB170I
**WARNING** DUE TO SYSUT3 I/O ERROR, COMPRESS IN-PLACE NOT DONE AND COPY OPERATION TERMINATED

Explanation

An I/O error has occurred while using the spill data set. None of the members were physically moved, so the data set remains as it was prior to processing.

The severity is 8.

System action

The operation is ended and the next control statement is sought.

System programmer response

Use the IEHLIST utility to investigate the output directory and determine which member(s) were not copied. If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the JCL and all printed output and output data sets related to the problem.

Programmer response

Retry the failing operation, and either:
  • Remove the SYSUT3 DD statement and increase the work area size. See message IEB1051I previously issued.
  • Use a different SYSUT3 data set. Place the SYSUT3 data set on a different physical location on the volume, on a different device, or on a different channel.

Source

Data Facility Product (DFP)

Routing code

Note 11