IEBA52I
VALUE OF LINES CONTRADICTS VALUE OF SIZE

Explanation

When building an FCB module for the 3800, 3262 model 5, or 4248 printer, the specifications for the LPI, LINES, and SIZE parameters on the FCB statement were conflicting.

System action

The IEBIMAGE program continues processing the next control statement, but writing to the library data set for the current operation is inhibited.

System programmer response

If the error recurs and the program is not in error, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the SYSOUT output, the source input for the job, and all printed output and output data sets related to the problem.

Programmer response

Respecify the FCB statement with complementary values for the LINES, SIZE, and LPI parameters. See the IEBIMAGE chapter in z/OS DFSMSdfp Utilities for the default value of each parameter.

Source

DFSMSdfp