IEC617I
DYNAMIC LPA REFRESH OF MODULE ModName text

Explanation

The system issues this message is in response to an SETPROG LPA, ADD operator command, or the addition of a PROG LPA, ADD statement in the PROGxx parmlib member that was activated with the SET PROGxx operator command. The data management module, ModName, could not be dynamically refreshed. The corrective service has not been activated in the system for this module.

text is one of the following:
FAILED DUE TO AN ERROR IN SYSTEM SERVICE SystemServiceName RETURN CODE IS ReturnCode
The problem was caused by an error in system service SystemServiceName with return code ReturnCode.
FAILED DUE TO ABEND CODE Code
The problem was caused by the hexadecimal system abend Code displayed.
FAILED DUE TO ABEND CODE xxx (without ModName specified)
A non-specific load module error occurred in detecting module IGG0DLPA. The problem was caused by the hexadecimal system abend Code displayed.

System action

Data management module, ModName, has not been refreshed.

Operator response

Notify your system programmer.

Programmer response

Perform the following steps:
  1. Analyze the return and reason code from the system service that did not complete to determine the cause of the problem.
  2. If you can correct the error, reissue the SETPROG LPA, ADD or SET PROGxx operator command at an MVS system console to refresh the data management module that the error was first seen.

    If you cannot resolve the error, schedule a system IPL to activate the corrective service.

Source

DFSMSdfp data management (DADSM)

Module

IGG0DLPA

Routing code

2,10

Descriptor code

5