Explanation
The system issues this message is in response to
an SETPROG LPA, ADD operator command, or the addition of a PROG LPA,
ADD statement in the PROGxx parmlib member that was activated with
the SET PROGxx operator command. The data management module, ModName,
could not be dynamically refreshed. The corrective service has
not been activated in the system for this module.
text is
one of the following:
- FAILED DUE TO AN ERROR IN SYSTEM SERVICE SystemServiceName RETURN
CODE IS ReturnCode
- The problem was caused by an error in system service SystemServiceName with
return code ReturnCode.
- FAILED DUE TO ABEND CODE Code
- The problem was caused by the hexadecimal system abend Code displayed.
- FAILED DUE TO ABEND CODE xxx (without ModName specified)
- A non-specific load module error occurred in detecting module
IGG0DLPA. The problem was caused by the hexadecimal system abend Code
displayed.
System action
Data management module, ModName,
has not been refreshed.
Operator response
Notify your system programmer.
Programmer response
Perform the following steps:
- Analyze the return and reason code from the system service that
did not complete to determine the cause of the problem.
- If you can correct the error, reissue the SETPROG LPA, ADD or
SET PROGxx operator command at an MVS system console to refresh the
data management module that the error was first seen.
If you cannot
resolve the error, schedule a system IPL to activate the corrective
service.
Source
DFSMSdfp data management (DADSM)
Module
Routing code
Descriptor code