The system continues processing.
If the device is pending offline and pending boxed and not allocated, use the D GRS,C=(SYSIEFSD,VARYDEV*) command to ensure no contention exists for SYSIEFSD.VARYDEV* resources. If all of the above conditions are met and no contention exists, notify the system programmer.
Verify that the SYSIEFSD.VARYDEV resource is not being used elsewhere through D GRS,RES=(SYSIEFSD,VARYDEV*). If it is, monitor the resource to ensure processes using it are releasing it as expected. If the resource is held by a process that seems hung, attempt to cancel the job. If cancel is not possible, contact IBM®.
Master scheduler
IEECB845, IEECB848
-
5