Explanation
The system did not activate a SLIP trap. In the
message text:
- xxxx
- The SLIP trap identifier specified on the SLIP command.
- text
- The reason that the trap was not activated. One of the following:
- FIRST RANGE ADDRESS SPACE WAS NOT ACTIVE.
- The address space qualifier for the first address of a range specified
an address space that is not active.
- SECOND RANGE ADDRESS SPACE WAS NOT ACTIVE.
- The address space qualifier for the second address of a range
specified an address space that is not active.
- FIRST RANGE ADDRESS COULD NOT BE DETERMINED.
- The system could not evaluate the first indirect address specified
in the SLIP command for one of the following reasons:
- The address space was swapped out.
- The page where the address resides was paged out.
- The page where the address resides was not valid.
- SECOND RANGE ADDRESS COULD NOT BE DETERMINED.
- The system could not evaluate the second indirect address specified
in the SLIP command for one of the following reasons:
- The address space was swapped out.
- The page where the address resides was paged out.
- The page where the address resides was not valid.
- RANGE OF A TARGET TRAP USES THE SA QUALIFIER BUT SOURCE TRAP IS
NOT SA.
- The SA qualifier was used in the RANGE parameter of a target trap,
but the source trap was not SA.
- DYNAMIC PER ACTIVATION CHAIN IS NOT COMPLETE.
- An attempt was made to enable the first trap in a dynamic PER
chain. However, not all the traps in the chain were present.
- RESPONSE WAS CANCEL.
- The command entered was SLIP MOD,ID=XXXX,ENABLE, but the range
was too large. The operator chose to cancel activation of the trap.
- COULD NOT RESOLVE PVTMODE RANGE.
- SLIP could not obtain the local lock of the primary address space
where the PER interrupt occurred. The local lock is required to search
the job pack queue.
- COULD NOT SET PER RANGE.
- The problem is caused by the timing of the command or the environment.
- INSUFFICIENT AUTHORITY
- The security FACILITY class entity IEASLIP.REFRESH is provided
for installations to permit the use of the REFBEFOR and REFAFTER keywords
on the SLIP command. When the IEASLIP.REFRESH FACILITY class profile
is defined, the SLIP command issuer must have UPDATE access to that
profile in order to use the REFAFTER and REFBEFOR keywords. Message
IEE406I 'SLIP TRAP ID=xxxx NOT ACTIVATED. INSUFFICIENT AUTHORITY'
is displayed if the command issuer does not have UPDATE access. The
security product may issue additional messages that are associated
with this message so you should look in the log for any additional
messages.
System action
The system does not activate the SLIP trap. The
system continues other processing.
Operator response
If the text was COULD NOT
SET PER RANGE, enter the SLIP command again. For any other text,
contact the system programmer.
System programmer response
Correct the problem indicated by the text.
Ask the operator to enter the SLIP command again.
Source
Module
Routing code
Descriptor code