IEE397I
form 1 or form 2

Explanation

form 1 is:
SMF DATA SET IS TOO SMALL AND WILL NOT BE USED, DSN=dsname
form 2 is:
SMF DATA SET IS TOO SMALL AND WILL NOT BE USED, DSN=
   dsname

The dsname recording data set is too small to hold the largest possible SMF record (32 kilobytes) and the control information that is required to segment the record.

Note: This message is issued instead of IEE960I only when an installation defines a data set name that does not use the SYS1.MANn naming convention.
In the message text:
dsname
The name of the SMF recording data set.

System action

SMF initialization or SET SMF command processing continues but ignores the dsname data set. If at least one valid SMF recording data set is available, SMF continues recording and issues message IEE388I. Otherwise, SMF will begin to buffer SMF data into storage until another data set becomes available.

Operator response

Notify the system programmer.

System programmer response

Recreate the dsname data set using the access method services DEFINE utility and specifying a larger size. Use the access method services LISTCAT utility to check the size of all SMF recording data sets. A data set is large enough if the LISTCAT output shows a HI-ALLOC-RBA value of at least 36863 for the data set. Recreate any data set that is too small.

Note: This message can be issued when the system tries to use an SMF data set that was created with extents. SMF data sets cannot have extents.

Source

System Management Facilities (SMF)

Module

IEEMB822

Routing code

2,10

Descriptor code