IEE395I
DSORG OF SMF DATA SET IS NOT VSAM AND CANNOT BE USED, DSN=dsname or DSORG OF SMF DATA SET IS NOT VSAM AND CANNOT BE USED, DSN=dsname

Explanation

System Management Facilities (SMF) found that the dsname recording data set specified in the DSNAME parameter in the SMFPRMxx parmlib member or in the reply to message IEE357A is not a VSAM data set. All SMF recording data sets must be VSAM data sets.

Note: This message is issued instead of IEE951I only when an installation defines a data set name that does not use the SYS1.MANn naming convention.
In the message text:
dsname
The name of the SMF recording data set.

System action

SMF initialization or SET SMF command processing continues. If at least one valid SMF recording data set is available, SMF continues recording and issues message IEE388I. Otherwise, SMF will begin to buffer SMF data into storage until another data set becomes available. If a data set does not become available, SMF data will be lost.

Operator response

Notify the system programmer.

System programmer response

Respond with one of the following:
  • Recreate the dsname data set.
  • Modify the DSNAME parameter in the SMFPRMxx parmlib member to include only VSAM data sets.

Source

System Management Facilities (SMF)

Module

IEEMB822

Routing code

2,10