IEE328I
cccccccc COMMAND ABORTED -[reason]

Explanation

The system could not run a command for one of the following reasons:
  • There is not enough storage available to schedule the command.
  • The system tried to obtain more address spaces than the maximum number supported.
  • Start of changeThe operator tried to issue a vary command to activate, deactivate, or go into standby mode for a console, or to set a device online or offline, but the command failed because of an abend.End of change
  • If the command is LOGON, MOUNT, or START, there is a shortage of available slots in the auxiliary storage paging space. The system also issues message IRA200E.
  • If the command is DISPLAY GRS or VARY GRS, an error occurred during global resource serialization processing.
  • If the command is DISPLAY APPC or DISPLAY ASCH, the storage area for the display is too small because extremely high APPC or APPC/MVS transaction scheduler activity occurred.
  • If the command is UNLOAD, the command failed for one of the following reasons:
    • An attempt was made to obtain an enqueue.
    • An internal error occurred during allocation UNLOAD processing and the UNLOAD command could not continue.
In the message text:
cccccccc
The command, or a portion of the command, entered.
ssssssss
The target system.
reason
One of the following:
TARGET SYSTEM ssssssss APPEARS STOPPED
The system could not deliver a command to another system in the sysplex for one of the following reasons:
  • The target system is quiesced.
  • The channel-to-channel (CTC) link between the source and target systems is not working.
TARGET SYSTEM ssssssss NOT READY FOR COMMANDS
The system on which the command was targeted for processing is still initializing and is not yet ready to process commands.
Start of changeERROR DURING ATTRIBUTE PROCESSINGEnd of change
Start of changeThe VARY command abended during Vary console attribute processing.End of change
Start of changeERROR DURING STANDBY PROCESSINGEnd of change
Start of changeThe VARY command abended during Vary console standby processing.End of change
Start of changeERROR DURING ACTIVATE PROCESSINGEnd of change
Start of changeThe VARY command abended during Vary console activation processing.End of change
Start of changeERROR DURING DEACTIVATE PROCESSINGEnd of change
Start of changeThe VARY command abended during Vary console deactivation processing.End of change

System action

The system rejects the command. The system may issue additional messages about a failed CTC or failed processor partitioning.

Operator response

Do one of the following:
  • Enter the command again at a later time.
  • Redirect the command to a different processor.
  • Restart the stopped system.
  • If the command is LOGON, MOUNT, or START, see message IRA200E for actions to relieve the auxiliary storage shortage.
  • If the command is DISPLAY GRS or VARY GRS, enter the command again. If the problem persists, stop entering GRS commands on this system. Re-IPL the system.
  • If the command is DISPLAY APPC or DISPLAY ASCH, enter the command again. If the problem persists, enter the command again, using the CLASS keyword parameter on DISPLAY ASCH or any of the keyword parameters on DISPLAY APPC.

System programmer response

If the command is VARY and the failure is caused by an internal error, collect documentation and contact L2.

Source

Consoles or MVS™ Device Allocation, Master Scheduler

Module

CNZK1RCN, IEAVG610, IEAVG616, IEECB808, IEECB820, IEECB833, IEECB837, IEECB838, IEECB839, IEECB840, IEECB841, IEECB842, IEECB844, IEECB845, IEECB846, IEECB847, IEECB848, IEECB849, IEECB850, IEECB851, IEECB852, IEECB853, IEECB856, IEECB857, IEECB858, IEECB905, IEEHB800, IEEMB813, IEE0803D, IEE7103D, IEE8303D, IEFHBPDF

Routing code

*

Descriptor code

5