IEC922I
016-08,jjj,sss,ddname,ATTEMPTED TO READ AN EXECUTE-ONLY DATA SET.

Explanation

An EXCPVR SVC request was issued on behalf of the user to read an EXECUTE-only data set. The attempt to read the data set failed. In the message text:
jjj
Job name
sss
Step name
ddname
ddname

System action

The task ends.

System programmer response

In the case of a single data set, change the RACF® access from EXECUTE to READ if it is determined that the program should have READ access to the data set. In the case of a data set concatenation, remove all EXECUTE-only protected data sets if it is determined that they are unnecessary since the entire concatenation is considered EXECUTE-only if any of its data sets are so protected.

Programmer response

Probable user error. In the case of a single data set, change the RACF access from EXECUTE to READ if it is determined that the program should have READ access to the data set. In the case of a data set concatenation, remove all EXECUTE-only protected data sets if it is determined that they are unnecessary since the entire concatenation is considered EXECUTE-only if any of its data sets are so protected.

Source

DFSMSdfp

Module

IGG019BX

Routing code

9,11

Descriptor code

4