Start of change
IEB1130W
A severity MESSAGE FROM {PDSE | FAMS} PROCESSING APPEARS ABOVE -- DIAGNOSTIC INFORMATION IS X'diagcode'

Explanation

The system encountered a problem while processing an operation that involved a PDSE Start of changeor PDSEnd of change. The diagnostic code displayed might be requested by the IBM Support Center, if you report the problem.

Note that this message can be displayed with different type code suffixes, as follows:
  • IEB1130I
  • IEB1130E
  • IEB1130W
In the message text:
severity
is one of:
  • WARNING
  • ERROR - an error severity appears as IEB1130W.
  • SEVERE ERROR- a severe error severity appears as IEB1130E.
  • TERMINATING - a terminating severity appears as IEB1130E.
diagcode
diagnostic information for use by the IBM Support Center, if you report the problem.

The severity is 0.

System action

Processing Continues.

System programmer response

To determine the cause of the error using the diagnostic information included in the message, see z/OS DFSMSdfp Diagnosis. In particular, if the diagnostic information is X'28xxnnnn', refer to the FAMS Reason Codes section of the book to determine the problem.

If the error recurs and the program is not in error, look at the messages in the job log for more information.

If you cannot resolve the problem, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM Support Center.

User response

Look at the accompanying IGW messages preceding this message for more information.

Programmer response

Refer to accompanying IGW and IEB messages, for more information.

Source

DFSMSdfp

End of change