IEE821E
SMCS APPLID VALUE HAS BEEN CHANGED ON sysname - SMCS MUST BE RECYCLED

Explanation

An operator has changed the SMCS APPLID on a system in the sysplex using the K M,APPLID= command. For the new APPLID to take effect, SMCS must be recycled on that system (using the VARY NET,INACT,ID=smcsapplid and the VARY NET,ACT,ID=smcsapplid commands).

System action

SMCS continues to use the previous APPLID on the system that is indicated in the message.

Operator response

SMCS should be recycled on the system indicated in the message.

Source

Communications Task

Module

IEAVC702

Routing code

*,2,10

Descriptor code

3