IEE820E
SMCS GENERIC VALUE HAS BEEN CHANGED - SMCS MUST BE RECYCLED ON SOME SYSTEMS

Explanation

An operator has changed the SMCS GENERIC using the K M,GENERIC= command. For the new GENERIC to take effect, SMCS must be recycled on every system in the sysplex (using the VARY NET,INACT,ID=smcsapplid then VARY NET,ACT,ID=smcsapplid commands.) There are systems in the sysplex that have not been recycled yet, and are still using the previous SMCS GENERIC.

System action

SMCS continues to use the previous GENERIC on every system that has not yet been recycled.

Operator response

SMCS should be recycled on every system that is not using the current GENERIC value. The DISPLAY CONSOLES,SMCS command may be issued to determine which systems need to be recycled.

Source

Communications Task

Module

IEAVC702

Routing code

*,2,10

Descriptor code

3