IEA927I
PLPA AND COMMON PAGE DATA SETS FULL FROM PREVIOUS IPL

Explanation

On a previous system initialization, the PLPA and COMMON page data sets were filled up during the write of the pageable link pack area (PLPA). The common storage area (CSA) and the rest of the PLPA have no primary slots.

System action

Initialization continues with the DUPLEX page data set. If there is no DUPLEX page data set, the system issues message IEA935W.

Operator response

Notify the system programmer.

System programmer response

If a warm start is necessary to clean up work in the system, ensure that the previous DUPLEX page data set is usable, then ask the operator to reIPL. Otherwise, redefine the PLPA and COMMON page data sets, then ask the operator to reIPL with the CLPA option.

Source

Auxiliary storage manager (ASM)

Module

ILRASRIM

Routing code

Note 9

Descriptor code

4