IEA854I
ERROR READING VOLUME LABEL.

Explanation

For processing of a VATLSTxx parmlib member, the system could not read the volume label on a device. The device address is specified in subsequent messages. One of the following occurred:
  • If message IEA306I precedes this message, an I/O error occurred when reading the label.
  • The volume does not contain a standard label.
  • In the case of Mass Storage System (MSS) volume, the volume serial number on the label does not match the volume serial number requested from the 3850 MSS. This case can occur when an MSS volume label has been clipped to a different serial number.

System action

For an MSS volume, the VATDEF entry is ignored; processing continues with the remaining VATLSTxx entries.

For non-MSS volumes the system waits for the operator to mount the correct volume, if all device addresses specified in reply to IEA851A have not yet had volumes mounted on them. If they have, the system does not wait; a mount request for the desired volume must be issued later.

Operator response

For MSS volumes, no response is necessary.

For non-MSS volumes:
  • If the wrong volume is mounted, remove it and mount the correct volume.
  • If no volume can be mounted (for example, there is an error on that device), and the device is listed in IEA860A, reply ’NO’ to message IEA893A when all other required devices have been mounted (that is, when the required devices are not listed on IEA893A).

Source

Allocation/unallocation

Module

IEAVAP00

Routing code

2

Descriptor code

12