Explanation
A TIMEZONE statement in the CLOCK
xx parmlib
member contains an incorrect specification:
- The syntax of the statement is incorrect
- The value is outside the correct range (00.00.00 - 15.00.00 hours).
In the message text:
- CLOCKxx
- The parmlib member, with the suffix xx.
- nnnn
- The line number in the CLOCKxx parmlib member
that contains the ignored statement.
System action
The system ignores all CLOCKxx parmlib
members. The system issues message IEA906A.
Operator response
Reply to message IEA906A. If you press the
enter button on the console, the system sets the following defaults:
- The system does not prompt the operator during time-of-day (TOD)
initialization.
- The system sets the local time equal to the Greenwich mean time
(GMT).
System programmer response
Check for misspelled parameters in
the CLOCKxx parmlib member. Ensure that the value
for TIMEZONE is within the valid range (00:00:00 - 15:00:00).
Source
Module
Routing code
Descriptor code