IEA496I
dev, volser, MIRRORING state, SSID=ssid, CCA=ca

Explanation

The state of the mirrored pair has changed. In the message text:
dev
The device number of the primary device of a mirrored pair.
volser
The volume serial number of the primary device of a mirrored pair.
state
The new state of the mirrored pair is one of the following:
OPERATIONAL
The copy of the primary of a mirrored pair to secondary is complete, and the primary to secondary devices are synchronized.
PENDING
Mirrored operation is starting or restarting. The primary and secondary devices are not yet synchronized.
FAILED
The mirrored pair has been terminated from the PENDING or OPERATIONAL state.
ssid
The ssid of the primary of the mirrored pair.
ca
The two-byte channel connection address or the primary device of the mirrored pair.

System action

None.

Operator response

The various formats of the IEA496I message is issued when the system detects a change of state for an online primary device of a mirrored pair. Follow your installation's procedures for reporting this error.

Note: Automation programs that monitor operator messages may want to monitor for the occurrence of these messages to assist with decisions concerning the availability of critical data.

Source

DASD device initialization/re-initialization

Module

IECCINIT