Explanation
SLIP processing encountered an error while determining
if program event recording (PER) should be active for a particular
address space. The accompanying SVC dump identifies the address space.
The
status of PER in the address space is unknown; consequently:
- PER might not be active in the address space in which it should
be active.
- PER might be active in an address space in which it should not
be active. PER interruptions might continue to occur in this address
space. They will not be processed by SLIP but can slow system performance.
System action
The system writes a logrec data set error record
and an SVC dump.
System programmer response
Do the following:
- Enter the SLIP trap again, specifying either:
- ACTION=IGNORE ASID=NONE to ignore the address space on the SLIP
trap.
- ASID=asid to trap the address space.
- If the problem continues, search problem reporting data bases
for a fix for the problem. If no fix exists, report the problem to
the IBM® Support Center. Provide
the SVC dump, the logrec data set error records, and messages.
Source
Module
Routing code
Descriptor code