Explanation
SLIP processing encountered an error while attempting
to activate or deactivate program event recording (PER) in an address
space. The accompanying SVC dump identifies the address space.
The
status of PER in the address space is unknown; consequently:
- If the error occurred while SLIP processing was attempting to
set or enable a PER trap, the trap might not be monitoring this address
space.
- If the error occurred while SLIP processing was attempting to
disable or delete a PER trap, PER interruptions might continue to
occur in this address space. They will not be processed by SLIP but
can slow system performance.
System action
The system writes an SVC dump.
System programmer response
Do the following:
- Try to correct the status of PER in the address space as follows:
- If the error occurred while SLIP processing was attempting to
set or enable a PER trap, ask the operator to enter SLIP MOD commands
to disable the same trap and then enable it.
- If the error occurred while SLIP processing was attempting to
disable or delete a PER trap, ask the operator to enter SLIP SET and
SLIP MOD commands to set and then disable a PER trap for an address
space that is not currently active in the system.
- If the status of PER cannot be corrected, search problem reporting
data bases for a fix for the problem. If no fix exists, report the
problem to the IBM® Support Center.
Provide the SVC dump.
Source
Module
Routing code
Descriptor code