The nucleus initialization program (NIP) could not find the module in the link pack area (LPA).
Except during special NIP processing, the system indicates which function was made inoperative by issuing message IEA208I, and then it continues processing. If the system cannot continue processing without the module, the system enters wait state X'03B'.
This is probably an installation error. Notify the system programmer.
If the error recurs and the program is not in error, search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center.
Ensure that the missing routine is in the LPA. If necessary, add the module to the SYS1.LPALIB and have the operator run a cold start.
The module must be defined in the parmlib list referenced by the modified link pack area (MLPA) or FIX option, if either of these options is used.
Contents supervision (CSV)
IEAVNPS5, IEAVNP05, IEAVNP07
2,10
4