IEATH005E
The timer synchronization mode in use on this system is ETR. A migration action is recommended.

Explanation

CHECK(IBMTIMER, ZOSMIGREC_SUP_TIMER_INUSE) found that the timing synchronization mode in use on this system was ETR (which uses the Sysplex Timer). Server Time Protocol is recommended because the Sysplex Timer (9037-002) has been withdrawn from marketing and STP is planned to be its replacement. The migration action to migrate from a Sysplex Timer to Server Time Protocol is applicable to this system.

The servers and coupling facilities that are capable of supporting STP are the z10™, z9®, z990, and z890. The STP feature number is 1021. STP is a server-wide facility that is implemented in the Licensed Internal Code (LIC) of z10, z9, z990s, z890s, and coupling facilities, and presents a single view of time to PR/SM™.

System action

Processing continues.

Operator response

Notify the system programmer.

System programmer response

See the z/OS® Migration book for information about migrating from a Sysplex Timer to Server Time Protocol. The Server Time Protocol website is http://www.ibm.com/systems/z/pso/stp.html.

Problem determination

N/A

Source

Timer Supervisor (TIMER)

Module

IEATCMSG

Routing code

N/A

Descriptor code

12 is the default set by this check

Automation

N/A

Reference Documentation

For more information about this migration action, see the z/OS Migration book.