Explanation
A check was not processed because one
of the following situations was detected:
- The specified date on the UPDATE request is older than the date
of the matching check. The check date is the date specified by the
DATE keyword of the HZSADDCK macro that added the check or the DATE
parameter of the ADD or ADDREPLACE statement of the HZSPRMxx parmlib
member that added the check.
- A SYNCVAL value was specified and an INTERVAL or EXCEPTIONINTERVAL
value did not obey the following rules:
- for SYNCVAL(hh:mm) and INTERVAL
OR EXCEPTIONINTERVAL(hhh:mm)
the (exception-) interval duration in total minutes hhh*60
+ mm has to be a divisor or a multiple of 1440
minutes (24 hours).
- for SYNCVAL(*:mm) and INTERVAL OR EXCEPTIONINTERVAL(hhh:mm)
the (exception-) interval duration value in total minutes hhh*60
+ mm has to be a divisor or a multiple of 60 minutes
(one hour).
In the message text:
- checkowner
- The owner of the check
- checkname
- The name of the check
System action
The system continues processing.
Operator response
System programmer response
For a DATE conflict, make
sure that the parameters and values on the UPDATE statement are appropriate
for the check. Reissue the UPDATE with a new date and any other changed
needed.
For a SYNCVAL conflict, change the SYNCVAL or INTERVAL
or EXCEPTIONINTERVAL value so that the INTERVAL or EXCEPTIONINTERVAL
duration is an appropriate divisor or multiple of 24 hours or one
hour respectively. To display the check values, issue the MODIFY hzsproc,DISPLAY,CHECK=(check_owner,check_name),DETAIL
command and find the values that are in conflict.
Problem determination
Module
HZSINPRM, HZSPKCHG, HZSMIMST
Routing code
Descriptor code
IBM® Health Checker