HZS0350E
IBM HEALTH CHECKER FOR Z/OS HAS SUSPENDED WRITING TO LOG STREAM logstream. RC: retcode REASON: rsncode ADDITIONAL ATTEMPTS WILL BE MADE TO USE THE LOG STREAM

Explanation

IBM Health Checker for z/OS could not use the specified log stream to save check output. The log stream will be used to save check output when the error condition has been cleared up.

In the message text:

logstream
The log stream name
retcode
The return code of the IXGWRITE request
rsncode
The reason code of the IXGWRITE request

System action

If the situation is transient, the system DOMs the message.

Operator response

None

System programmer response

If the situation is not transient, then take action to correct the error.

Problem determination

None

Module

HZSTKLG1

Routing Code: 1,2,10

Descriptor Code: 11,7

IBM® Health Checker for z/OS®