Explanation
The system could not process a MODIFY
hisproc command
because the CTRSET or SAMPTYPE parameter values requested are either:
- Not supported on this CPU
- Not installed on this CPU
- Are not authorized for use
The
SAMPTYPE specifies
the sampling facility types you want to collect on a data run:
- The B (basic) sampling facility is installed
and available on all the IBM System z10 or
later machines. However, you must authorize the sampling facility
through the SE console explicitly.
- The D (diagnostic) sampling facility availability
is CPU model dependent and installation is optional. This sampling
facility also requires explicit authorization through the SE console.
For information about how to set up the authorization
of the sampling facilities, see Support Element Operations Guide for
System z10 machine on the Resource Link home page.
In
the message text:
- hisproc
- The name of the HIS cataloged startup procedure.
- failure-text
- The failure-text explaining the problem is
one of the following ones:
- BASIC COUNTER SET IS UNAUTHORIZED
- The Basic counter set is unavailable.
System programmer action: Ensure
that you authorize the indicated counter set for use by the hisproc HIS
Catalogued startup procedure.
- PROBLEM-STATE COUNTER SET IS UNAUTHORIZED
- The Problem-state counter set is unavailable.
System programmer
action: Ensure that you authorize the indicated counter set for
use by the hisproc HIS Catalogued startup procedure.
- CRYPTO-ACTIVITY COUNTER SET IS UNAVAILABLE
- The Crypto-activity counter set is unavailable.
System programmer
action: Ensure that the indicated optional counter set, if desired,
is installed and authorized for use by the hisproc HIS
Catalogued startup procedure.
- EXTENDED COUNTER SET IS UNAVAILABLE
- The Extended counter set is unavailable.
System programmer
action: Ensure that the indicated optional counter set, if desired,
is installed and authorized for use by the hisproc HIS
Catalogued startup procedure.
- ZOS COUNTER SET IS UNAVAILABLE
- The z/OS counter set is
unavailable.
System programmer action: Ensure that the Enhanced
Monitor Facility, if desired, is installed for use by the HIS catalogued
startup procedure.
- MT-DIAGNOSTIC COUNTER SET IS UNAVAILABLE
- The MT-diagnostic counter set is unavailable.
System programmer
action: Ensure that the hardware supports multithreading (MT)
and requests multithreading exploitation via the PROCVIEW CORE parameter
in the LOADxx parmlib member.
- BASIC SAMPLING FUNCTION IS UNAUTHORIZED
- The Basic sample function is unavailable.
System programmer
action: Ensure that you authorize the basic sampling function
for use by the hisproc HIS Catalogued startup procedure.
- DIAGNOSTIC SAMPLING FUNCTION IS UNAVAILABLE
- The Diagnostic sample function is unavailable.
System programmer
action: Ensure that the indicated optional sampling function is
installed and authorized for use by the hisproc HIS
Catalogued startup procedure.
- NO COUNTER SETS ARE AVAILABLE
- No counters are installed or authorized.
System programmer
action: Ensure that you authorize the indicated counter set for
use by the hisproc HIS Catalogued startup procedure.
System action
The system does not process the command issued.
Operator response
Ensure that all the specified counter sets
(CTRSET parameter) or sampling facility types (SAMPTYPE parameter)
are installed and authorized on this system.
System programmer response
See the System programmer action in
the explanation for the particular failure text displayed.
Problem determination
Source
Hardware instrumentation services (HIS)
Module
Routing code
Descriptor code