During a data collection run initiated by the MODIFY hisproc command with parameter MAPJOB (but not MAPASID), the system found that it could not match any active address spaces from the list specified on the MAPJOB parameter. HIS will not produce any private load module information, but will produce mappings of the LPA and the nucleus.
The system issues this informational message only if it is unable to match any active address spaces from the information specified on the MAPJOB parameter (but not MAPASID) or if no MAPASID parameter has been specified.
The system continues processing.
Issue the command again if necessary, specifying one or more active address spaces on the MAPJOB parameter. If private load module map information is not needed, you can let the current data collection continue proceeding.
None.
None.
Hardware instrumentation services (HIS)
HISPCMD
2
4