IEA797W
{THE POINTER TO THE CURRENT FRR STACK IS NOT VALID.| AN FRR STACK POINTER IS DAMAGED.}

Explanation

A recovery termination manager (RTM) first level interruption handler (FLIH) determined that an interruption is an error. The FLIH issued a CALLRTM macro to recover or to end the routine that caused the error. While processing the request, RTM found uncorrectable damage to at least one functional recovery routine (FRR) stack pointer in the recovery stack vector table (PSARSVT) of the prefixed save area (PSA).

System action

The system:

  1. Issues this message.
  2. Places all processors on this system in non-restartable X'084' wait state, with reason code X'04'.

Operator response

See the operator response for wait state X'084'.

System programmer response

See the system programmer response for wait state X'084'.

Source

Recovery termination manager (RTM)

Module

IEAVTRTV

Routing code

1

Descriptor code

1