OPTIONS FOR OPERATIONS COMPONENT TRACE ARE NOT VALID.
Explanation
One of the following occurred:
- The OPTIONS keyword, specified on the REPLY command in response
to a TRACE CT,ON,COMP=SYSOPS command, was entered with incorrect options.
- The operations component trace parmlib member specified on a TRACE
CT,ON,COMP=SYSOPS,PARM=CTIOPSxx command contains incorrect options
on the OPTIONS keyword.
- The operations component trace parmlib member specified at IPL
contains incorrect options on the OPTIONS keyword.
Valid options are:
- MESSAGES{,MSG=msgid}
- MSGDLVRY{,MSG=msgid}
- SYSPLEX
- WTO{,MSG=msgid}
- MCACHE
- RECOVERY
- SERIALIZ
- CONSDATA
- COMMAND
- Combination of above options
System action
If the error occurred during use of the TRACE
CT command, the command is rejected. If the error occurred during
system initialization, operations component trace (SYSOPS) is initialized
with the default tracing options.
Operator response
Do one of the following:
- If the options were specified on the REPLY command, re-enter the
TRACE command and specify the correct options on the REPLY command.
- If the options were contained in an operations CTRACE parmlib
member that was specified on the PARM= keyword of the TRACE CT command,
have the system programmer correct the parmlib member. When the parmlib
member has been corrected, re-enter the TRACE CT command.
- If this message was issued during initialization, wait for the
system initialization to complete and then enter the DISPLAY TRACE,COMP=SYSOPS
command to display the current tracing options. If the desired options
are not in effect, enter the TRACE CT command to change operations
tracing activity as needed. Notify the system programmer that the
parmlib member that was used contains errors.
System programmer response
If the incorrect options were listed
in an operations CTRACE parmlib member, correct the parmlib member.
Notify the operator when the parmlib member has been corrected.
Source
Communications Task (COMMTASK)
Module
Routing code
Descriptor code