Explanation
An attempt to write data from cache to DASD encounters
a DASD track format incompatible with the operation. In the message
text:
- vvvvvv
- The volume that failed.
- cccCCCC:H
- Normalized hexadecimal cylinder/head address of the failing track.
- reason-code
- The reason code of the failure. See IBM 3990/9390 Storage Control Reference,
Chapter 5, “Sense Byte Information” under the heading Format F Message
7.
- device-number
- The physical device address.
- ssid
- The subsystem identifier.
- p
- The storage path.
- cc
- The controller address.
- nn
- The device number.
- sense
- The 32 characters of sense data reported by the device.
xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx
System action
If the destage is for a fast write, the track
is pinned in cache/nonvolatile storage. If the destage is to a duplex
pair, the duplex pair is suspended.
Operator response
Follow your installation's procedures for
reporting this error. If the device associated with this message is
attached via the IBM® 3990 Model
3 or Model 6 Storage Control, see IBM 3990
Operations and Recovery Guide for detailed recovery actions.
Source
Module