IEA400I
NSYSLX VALUE, value, NOT VALID, DEFAULT OF number USED

Explanation

During system initialization, the number of system linkage indexes, NSYSLX, was incorrectly specified in one of two ways:
  • In the IEASYSxx parmlib member
  • In the operator response to message IEA101A
In the message text:
value
The incorrect NSYSLX value, which is less than 10 or greater than 512
number
The default value for NSYSLX. This is currently 165.

System action

Initialization continues with the default NSYSLX value of 165.

Operator response

In response to message IEA101A, enter a new NSYSLX value specified by the system programmer. If message IEA101A does not appear, reIPL to enter a correct value.

System programmer response

Respecify the number of system linkage indexes by doing one of the following:
  • Ask the operator to enter a correct value in response to message IEA101A.
  • Correct the value specified in the IEASYSxx member.

Source

Supervisor control

Module

IEAVNPO9

Routing code

2,10

Descriptor code

4