Explanation
The return code and reason code were returned by
catalog management module ARCUTIL, DEVINFO, or VVAS as a result of
an exceptional condition. The VOLSER line will only be output if the
failure was from the VVAS.
In the message text:
- function
- The name of the function that was processing when the error occurred.
- return-code
- The return code.
- reason-code
- The reason code.
- volser
- The Volume Serial number. (Only if VVAS failure.)
System action
Processing associated with the error return code
is ended.
System programmer response
If the error recurs and the program
is not in error, look at the messages in the job log for more information.
Search problem reporting data bases for a fix for the problem. If
no fix exists, contact the IBM® Support
Center. Provide the JCL, the SYSOUT output for the job, and all printed
output and output data sets related to the problem.
A list of
the return and reason codes follow for each function affected:
- Function
- MIGRATION DATA COLLECTION SERVICE
- Code
- Reason Explanation
- 04
- Incorrect parameter list.
- 01
- UPID not equal to UPIDNAME.
- 02
- UPVERS incompatible with current version used by ARCUTIL.
- 03
- Data control block (DCB) address not provided.
- 04
- No functions to perform.
- 05
- Incorrect combinations of options.
- 08
- Error opening DFHSM control data set.
- 01
- DFSMShsm MCDS
could not be opened.
- 02
- DFSMShsm BCDS
could not be opened.
- 10
- The VTOC for this volume is not an MVS™ VTOC.
CVAF/DADSM will only work with MVS VTOCs.
- 0C
- Error reading DFSMShsm control
data set.
- 01
- More than 10 read errors occurred accessing the DFSMShsm MCDS.
- 02
- More than 10 read errors occurred accessing the DFSMShsm BCDS.
- 03
- User specified DUMMY on the MCDS or BCDS DD statement. This is
not accepted when requesting the corresponding MCDS/BCDS statistics.
- 10
- Error writing to the output data set.
-
- The reason code contains the contents of register 1 received from
the SYNADAF macro.
- 14
- An abnormal end occurred.
-
- The reason code contains the system completion code.
- Function
- DEVICE INFORMATION SERVICE
- Code
- Reason Explanation
- 00
-
- 10
- 04
- Storage for the parameter list is not owned by the caller.
- 08
- Size of parameter list is incorrect.
- 0C
- Storage for the return area is not provided or is not owned by
the caller.
- 10
- Storage for the volume serial list is not owned by the caller.
- 14
- Storage for the device number list is not owned by the caller.
- 18
- Storage for the PDAREA is not provided, is not owned by the caller,
or is too small.
- 1C
- Storage for the return area is too small to contain at least a
header and one entry.
- 20
- A bad resume code was passed by the caller.
- 24
- No matches were found; search arguments given are too restrictive.
- 28
- No requests specified.
- 2C
- Incorrect parameter list level.
- 30
- Conflicting features request.
- 34
- Incorrect device number passed.
- 38
- Incorrect device number passed.
- 3C
- A release call was made but there was no storage to free.
- 14
- 04
- The pointer in JESCT to the EDT is zero.
- 18
- An error return code was received from common filter services.
- 1C
- An abend occurred.
- 20
- A nonzero return code was returned from IEFEB4UV.
- 24
- A nonzero return code was returned from DEVTYPE.
- Function
- VTOC/VVDS ACCESS SERVICE
- Code
- Explanation
- 08
- An error occurred while accessing the volume table of contents
(VTOC). The reason code contains the CVAFFILT return code. See z/OS DFSMSdfp Diagnosis
for more information about the CVAF reason code.
- 0C
- An error occurred while accessing the VSAM volume data set (VVDS).
The reason code contains the VVDS Manager return code. See the list
of reason codes for IDC3009I, return code 50.
- 10
- Processing error. The reason code is the SVC number.
- 20
- Parameter list error.
Source