ERB471I

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

ERB471I
PPS: SMF RECORD tt, SUBTYPE ss DATA INCOMPLETE - SYSPLEX xxx, COUPLING FACILITY yyy, SYSTEM zzz, INTVSTART mm/dd/yyyy hh.mm.ss

Explanation

SMF data from system zzz within sysplex xxx for coupling facility yyy and reporting interval start at mm/dd/yyyy hh.mm.ss does not cover the whole sysplex reporting interval. This message is repeated every time incomplete data is detected. In addition the note "DATA FROM SEVERAL SYSTEMS IS MISSING OR INCOMPLETE! REPORTED DATA MAY BE INEXACT!" is written on each of the coupling facility report parts. In the Coupling Facility Subchannel Activity report and the Coupling Facility Structure Activity report every system name for which data is not complete is marked with a "*".

System action

The Postprocessor creates the coupling facility reports indicating incomplete data.

User response

Check the SMF dataset.

Source

Resource Measurement Facility™ (RMF™)