ERB241I z/OS MVS System Messages, Vol 5 (EDG-GFS) SA38-0672-00 |
|
ERB241I sid: ABEND U1402 - INVALID ENTRY CODE
TO DATA GATHERER OR DATA REPORTER ExplanationDuring the RMF™ Postprocessor session or Monitor II session sid, a data gatherer or data reporter issued return code 8 to indicate that it detected an incorrect entry code in its input parameters. System actionIf the error occurred after the display session had been successfully initialized, RMF issues message ERB235A to let the operator decide whether or not to continue the session. When RMF cannot issue ERB235A, RMF ends the session. If the error occurred during a background session, RMF ends the session. If the error occurred during either a display or background session, RMF continues processing all other active sessions. If the error occurred during the Postprocessor session, RMF stops printing the Monitor II session report that was in process. If other reports were requested, the Postprocessor continues with them. The system writes an ABEND dump for the failing job step. Operator responseFor a display or background session or for the Postprocessor, respond to user completion code 1402. For a display session, respond to message ERB235A, if issued. System programmer responseObtain the SYSOUT output for the job. Search problem reporting data bases for a fix for the problem. If no fix exists, report the problem to the IBM® Support Center. SourceResource Measurement Facility™ (RMF) Routing code2 Descriptor code4 |
Copyright IBM Corporation 1990, 2014
|