z/OS MVS System Messages, Vol 5 (EDG-GFS)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


ERB239I

z/OS MVS System Messages, Vol 5 (EDG-GFS)
SA38-0672-00

ERB239I
sid: ABEND U1405 FROM ERBPUTSM - INPUT ERROR

Explanation

During display session sid, RMF™ module ERBPUTSM was called to add a text string to the logical terminal buffer, but the length specified for the text was zero.

System action

If the error occurred after the session had been successfully initialized, RMF issues message ERB235A to let the operator decide whether or not to continue the session. When RMF cannot issue ERB235A, RMF ends the session. In either case, RMF continues processing all other active sessions.

The system writes an ABEND dump for the failing job step.

Operator response

If an installation-supplied reporter module caused the error, notify the responsible programmer. If an IBM-supplied module caused the error, respond to user completion code 1405 and to message ERB235A, if issued.

System programmer response

Obtain the SYSOUT output for the job.

Search problem reporting data bases for a fix for the problem. If no fix exists, report the problem to the IBM® Support Center.

Source

Resource Measurement Facility™ (RMF)

Routing code

2

Descriptor code

4

Go to the previous page Go to the next page